yes

Sika Solutions for Steel components not subject to BSA:

Standard epoxy, solvent free, high chemical resistance, 3 layers application:

  • Sikagard®-63 N


Sika Solutions for Structural Steel Work not subject to BSA.
Coating systems for structural steel have to fulfil the requirements in accordance to EN ISO 12944:

System build up for corrosive industrial and maritime climate based on 2-comp. products:

  • SikaCor® EG-System


System build up for maintenance:

  • Sika Poxicolor® Primer HE NEU followed by an UV resistant, 2-component polyurethane top coat
    SikaCor® EG-5
    .